Daylight Factor and BS EN 17037 Explained

Daylight factor is the oldest measure of daylight inside a room and BS EN 17037 is the standard that now sets the targets for new homes. This guide explains how daylight factor is calculated, what the 2022 BRE guide asks for in new dwellings, what climate-based daylight modelling adds and how the figures are used at planning.

What daylight factor is

The daylight factor at a point inside a room is the illuminance at that point from daylight alone, divided by the illuminance outside under an unobstructed overcast sky, expressed as a percentage. A daylight factor of 2 per cent means that when it is 10,000 lux outside, the point receives 200 lux. The sky used is the standard overcast sky, which gives the same answer whatever the orientation of the window and whatever the time of year, which is why the measure has been used for a century.

The factor is made up of three parts: the sky component, light arriving directly from the sky; the externally reflected component, light bounced in from buildings and the ground; and the internally reflected component, light bounced around the room from its walls and ceiling. Window size, glazing transmittance, the depth of the room and the lightness of its finishes all change the result, which is what makes daylight factor a measure of the room rather than of the window.

Average daylight factor

For many years the planning target was the average daylight factor across a room, with 2 per cent for kitchens, 1.5 per cent for living rooms and 1 per cent for bedrooms taken from the old British Standard BS 8206-2. The 2011 BRE guide gave a simple formula for estimating it from the window area, its transmittance, the angle of sky visible from the window and the room’s surface area and reflectance. That formula is still useful at sketch design, but the 2011 targets have been replaced.

What BS EN 17037 changed

BS EN 17037, the European standard for daylight in buildings adopted in the UK in 2018, sets targets as illuminance rather than as a factor. The 2022 BRE guide adopts them for new dwellings. Each habitable room has a target illuminance to be achieved from daylight alone across at least half of its reference plane for at least half of the daylight hours in the year: 100 lux in bedrooms, 150 lux in living rooms and 200 lux in kitchens, with a combined living-kitchen room taken at the higher figure. The standard also sets levels for a view out and for sunlight, with at least 1.5 hours of sun on 21 March to a habitable room as the minimum.

Because the target is defined over hours in the year, it can be checked in two ways. The full method is climate-based daylight modelling, which runs the room under a year of recorded sky conditions for the location and counts the hours. The simpler method, which the standard allows, converts the illuminance target into a daylight factor using the median external illuminance for the location. For London the targets convert to a median daylight factor of roughly 1 per cent for bedrooms, 1.5 per cent for living rooms and 2 per cent for kitchens. The factor is checked at the median point of the room rather than as an average.

Climate-based daylight modelling

Climate-based daylight modelling, or CBDM, replaces the fixed overcast sky with a year of real weather data. It produces measures such as spatial daylight autonomy, the proportion of a room that reaches a target illuminance for a set share of occupied hours. It shows the difference between a north-facing and a south-facing room, which daylight factor cannot. It is more work and needs more assumptions about blinds and occupancy, so it is used on larger schemes, schools and where a design is close to the targets and the orientation helps.

How the figures are used at planning

For a scheme creating new homes, the daylight and sunlight report shows the target and the achieved figure for every habitable room, usually on a floor-by-floor plan with the rooms that do not meet the recommendations marked. Single-aspect north-facing flats, deep plans, ground floor rooms under overhangs and rooms behind a balcony are where shortfalls appear. Officers look at the proportion of rooms meeting the targets across the scheme and at whether the shortfalls are in bedrooms or living rooms. Where a room does not meet the recommendations the report should explain why and what, if anything, could be changed. Our guide to the full set of planning tests puts this alongside the tests for neighbouring windows.

If you are designing flats or a conversion and want the internal daylight checked before the application goes in, send us the plans and sections. We quote within 24 hours, Monday to Friday.

Frequently asked questions

5

What is a good daylight factor for a living room?

Under the 2022 BRE guide and BS EN 17037, a median daylight factor of about 1.5 per cent in London, equivalent to 150 lux for half the daylight hours over half the room. Kitchens need about 2 per cent and bedrooms about 1 per cent.

5

Is average daylight factor still used?

The 2011 average daylight factor targets have been superseded for planning, though the formula is still a useful early check and some older local policies refer to it.

5

What is the difference between daylight factor and VSC?

Daylight factor is measured inside the room and includes the window and the room’s finishes. The vertical sky component is measured outside at the window and describes only the sky available.

5

Do I need climate-based daylight modelling?

Not usually for small schemes. The daylight factor route is accepted by the standard. CBDM is worth it on larger schemes or where orientation makes a real difference to the result.

Get in Touch

We will be in touch to discuss your situation within one working day, free of charge.

    *Note - We will not share your personal details with any third parties, and you will not receive any email communication from us outside of direct correspondence in relation to your enquiry.

    Our Location

    Blue Sky Surveyors
    Office 7, 35-37 Ludgate Hill
    London
    EC4M 7JN

    Contact Information

    Phone: +020 7867 3955
    Email: info@rightsoflightsurveyors.co.uk

    Daylight Factor and BS EN 17037 Explained