The 25 degree rule is the quick check in the BRE guide for a building opposite a window. If the new building sits below a line at 25 degrees from the centre of the lowest affected window, daylight is unlikely to be a problem. This guide explains how it is drawn, what it means for sunlight and what happens when a scheme rises above the line.

What the rule says

Stand at the centre of the lowest window in the neighbouring building that faces the site and draw a line upwards at 25 degrees to the horizontal towards the proposed building. If the whole of the new building sits below that line, the BRE guide says the daylight to the existing building is unlikely to be significantly affected and no further daylight calculation is needed. If any part of the building rises above the line, the daylight to the windows facing it may be affected and the fuller tests, in particular the vertical sky component, should be run.

The line is drawn in section, across the gap between the two buildings, from the window centre on the existing building to the proposed building. It is measured from the lowest window because that is the one with the least sky and the most to lose. Where the new building is long and low, or set back behind a street, it will often pass; where it is taller than the gap is wide, it will not. A rough guide is that a building passes the 25 degree line when its height above the window centre is less than about half the distance between them.

The rule and sunlight

The same line is used as a quick check for sunlight, with one addition. Sunlight only matters to windows facing within 90 degrees of due south, so a new building below the 25 degree line, or more than 90 degrees from south of the window, is unlikely to affect sunlight. Above the line and within that arc, the probable sunlight hours calculation is needed.

Where it comes from

A window whose obstruction sits below 25 degrees retains roughly the 27 per cent vertical sky component that the guide treats as good daylight, which is where the angle comes from. The rule is a geometric shortcut to the VSC test rather than a separate standard. That also means a window already obstructed above 25 degrees, which describes most windows in a city, cannot be checked this way and goes straight to the full calculation.

The 25 degree rule and the 45 degree rule

They answer different questions. The 25 degree rule is for a building opposite a window, across a gap. The 45 degree rule is for an extension beside a window, on the same side of the boundary. It is drawn in plan as well as elevation. A rear extension to the house next door is a 45 degree question; a block of flats across the road is a 25 degree question. Both are quick checks and both give way to the measured tests when a line is crossed.

What happens above the line

Rising above the 25 degree line is not a refusal. It triggers the proper tests: VSC and no sky line for daylight, probable sunlight hours where the orientation calls for it. A great many schemes that cross the line keep every affected window within the BRE ratios, because the line is deliberately cautious. Where the full tests show a result that does not meet the recommendations, the design can often be adjusted by setting back the top floors or lowering the part of the building nearest the lowest window. Our guide to the full tests explains what follows.

The rule and rights of light

The 25 degree rule is a planning check. It has no bearing on whether the windows opposite have a right to light, which is tested by the Waldram method on the rooms behind them. A building that passes the 25 degree line can still infringe a right to light, especially where the rooms are deep or already poorly lit.

If your scheme rises above the line, or a neighbour’s does, send us the drawings and we will run the tests that matter.

Frequently asked questions

5

Is the 25 degree rule in the BRE guide?

Yes. It is the first daylight check in Site Layout Planning for Daylight and Sunlight, drawn from the centre of the lowest window facing the new building.

5

Does the 25 degree rule apply to extensions?

It is meant for buildings opposite a window. An extension beside a window is checked with the 45 degree rule instead.

5

What if the existing obstruction is already above 25 degrees?

Then the quick check cannot be used and the full vertical sky component test is run, comparing the before and after values.

5

Does passing the 25 degree rule mean no daylight report is needed?

For daylight to that window, the guide says no further calculation is needed. A council may still ask for a report on other windows, on sunlight or on the daylight within the new homes.

Get in Touch

We will be in touch to discuss your situation within one working day, free of charge.

    *Note - We will not share your personal details with any third parties, and you will not receive any email communication from us outside of direct correspondence in relation to your enquiry.

    Our Location

    Blue Sky Surveyors
    Office 7, 35-37 Ludgate Hill
    London
    EC4M 7JN

    Contact Information

    Phone: +020 7867 3955
    Email: info@rightsoflightsurveyors.co.uk

    The 25 Degree Rule for Daylight Explained